Cryogenic Deflashing and Deburring: Process, Machines and Liquid Nitrogen Use

Cryogenic deflashing removes flash from molded rubber, silicone and plastic parts. The parts are chilled until the flash turns brittle, then tumbled and blasted with plastic media until it snaps off. The part itself survives because it’s much thicker than the flash and stays tough for longer. Run the same machine on machined parts instead of molded ones and it’s called cryogenic deburring.
Machine makers publish basket volumes and wheel speeds. What they don’t publish is how much liquid nitrogen the machine uses. This guide covers how the process works, how cold it needs to be, what the machines are, and then works out that missing number and how to supply it.
In a hurry? Book a free LN2 supply audit and we will size your shop’s supply from your real usage.
Deflashing or deburring? The difference is where the waste came from
It’s the same machine working on two different defects.
- Flash is molding waste. When a tool wears or vents poorly, material escapes between the mold halves and leaves a thin skirt along the parting line. Flash belongs to molded and die-cast parts.
- A burr is machining waste. A cutting tool pushes material up at the edge of a cut and leaves a raised lip. Burrs belong to machined parts.
Both are thin, both hang off an edge, and both turn brittle before the part they’re attached to. The whole process depends on that.
How the process works
- Load. Parts go into a perforated basket. Barwell’s rule is to fill the basket only one third full, because the parts have to tumble freely. That’s why data sheets quote a gross basket volume and a much smaller usable one.
- Cool. Liquid nitrogen is injected into an insulated chamber, where it boils and fills the chamber with cold gas. The gas chills the parts. They’re never dunked in liquid, and that matters: rubber in direct contact with liquid nitrogen can absorb it and crack.
- Tumble and blast. The basket rotates, at up to 40 rpm on a Barwell machine, while a wheel throws cryogenic-grade polycarbonate media at the parts. On PEGE’s published range, the media leaves the wheel at roughly 105 to 145 m/s.
- Separate. Media and flash fall through the basket to a separator. The media is recycled, and the flash and dust are thrown away.
- Warm. Parts come back to room temperature, ideally under dry air or a nitrogen purge so moisture doesn’t condense on them.
Cycle times are short. PEGE and Jucai both publish ranges of a few minutes. Nitrofreeze describes cycles running “from a few minutes to as high as thirty minutes,” depending on batch size and how buried the flash is.

How cold, and why not colder
The number that matters isn’t the glass transition temperature. It’s the brittleness temperature, the point where a material fractures under impact instead of deforming. Rubber compounds are tested for it under ASTM D2137 and plastics under ASTM D746. Both tests hit a sample at temperature, which is exactly what a media blast does.
Machines are built for roughly plus 120°F down to minus 200°F, and that cold limit is about the same across makers. PEGE and Jucai publish minus 202°F, Cryogenic Systems and Parts publishes minus 205°F, and Nitrofreeze processes parts “as cold as minus 200°F.” Production set points sit above that floor and are chosen per material.
Silicone shows why glass transition is the wrong guide. Dow Corning’s published work on low-temperature silicone puts its glass transition near minus 175°F to minus 184°F, colder than most of these machines ever run. What actually stiffens silicone is partial crystallization. Under fast cooling, which is what a cryogenic chamber does, that starts nearer minus 85°F. The flash is brittle long before the chamber gets anywhere near the glass transition.
Fluoroelastomers sit at the other end and need very little cold. For Viton, Chemours publishes a low-temperature retraction figure (TR-10) rather than a glass transition. For the common grades it falls between about 21°F and minus 22°F.
Good to know: going colder than you need doesn’t help. Once the flash is brittle, extra cold removes nothing more, costs nitrogen in direct proportion, and starts to embrittle the part itself. Push a thin-walled part far past what it needs and you can crack it.

Where the process runs out
The process relies on one thing: the flash is thinner than the part, so it gets colder faster. Cryogenic Systems and Parts makes the point directly. If the flash and the part are the same thickness, the machine will remove both. Every limit below comes from that.
- Flash has to be thin. PEGE’s published design rule is flash under 0.2 mm on rubber and under 0.15 mm on plastic. Cryogenic Systems and Parts asks for a parting line of 0.005 inches or less for best results. Thicker flash needs a mechanical trim first.
- Features have a floor. For holes and cavities smaller than about 0.015 inch (0.38 mm), Nitrofreeze recommends dry ice instead, because polycarbonate media loses its bite in openings that small.
- Thin walls embrittle too. On thin-wall parts, the gap between flash and part shrinks, and so does the process’s selectivity.
- Metal inserts are a risk. Rubber-to-metal bonded parts can get scratched against their own insert during tumbling.
- Media can lodge. Blind pockets and undercuts trap media. Medialess tumbling and dry ice variants exist for those parts.
- It won’t fix a molding problem. A worn tool that makes heavy flash keeps making heavy flash. Deflashing doesn’t replace tool maintenance.
The machines
| Machine | Usable basket | Published detail |
|---|---|---|
| Nitrofreeze | 1.0, 1.2, 1.6 and 3.0 cubic feet | Throw wheel to 20,000 rpm, cryogenic-grade polycarbonate media |
| Barwell Freeze Trim-NX | Four sizes | Basket one third full, rotation to 40 rpm, 25 mm foam insulation (50 mm on the largest), parts to 250 mm diameter |
| Cryogenic Systems and Parts, SCC and LCC | 0.75 to 6 cubic feet | Minus 205°F, 51 mm urethane insulation, media 0.015 to 0.060 inches |
| PEGE PG-40T to PG-150T | 15 to 50 liters | 150 to 600 kg of parts per day, minus 202°F to plus 122°F, media 105.7 to 145.3 m/s, barrel 0 to 25 rpm |
| Jucai SD-A to SD-XL | 30 to 155 liters | 5 to 13 kW, minus 202°F to plus 122°F, cycles of 1.5 to 10 minutes |
| Showtop NS-60T | 60 liter basket | Quoted at 60 kg per hour on rubber O-rings; rubber, silicone, PEEK, plastic, and zinc, aluminum and magnesium die castings |
PEGE’s kilograms-per-day figure is rare in this industry, and it’s the useful one, because it converts straight into a nitrogen budget.
Choosing the media
Media is cylindrical, cryogenic-grade polycarbonate. Published sizes run from about 0.015 to 0.080 inches (0.4 to 2.0 mm), rated for cryogenic service down to minus 200°F. Suppliers color-code the sizes so operators can tell them apart at changeover, and also sell cubes for flash that needs more energy. Bigger media hits harder and smaller media reaches into detail. Media that’s too aggressive for the part will damage it.
How much liquid nitrogen does a deflashing machine use?
You can work it out from the physics. Liquid nitrogen absorbs about 199 kJ per kilogram as it boils, roughly 160 kJ per liter. If the cold exhaust gas keeps picking up heat on the way out, a liter can do up to about twice that work. A deflashing machine spends that cold on four things: the parts, the media and basket, the chamber itself, and heat leaking in while the cycle runs.
Here’s a worked example: a mid-size machine at a minus 148°F set point, which means a 216 degree pull-down.
| Item | Assumption | Heat to remove | LN2 at boiling heat only |
|---|---|---|---|
| Parts | 10 kg of rubber, about 1.3 kJ/kg/K averaged | ~1,560 kJ | ~10 L |
| Basket | 8 kg of steel | ~380 kJ | ~2.5 L |
| Heat leak | 6 minute cycle, insulated chamber | ~400 kJ | ~2.5 L |
| Media and chamber | 15 kg of media plus chamber steel, first cycle of the day only | ~2,500 kJ | ~16 L |
In steady production the media and chamber stay cold, so a cycle costs on the order of 15 liters, and less once the cold exhaust does part of the work. As a planning figure, use about a liter of liquid nitrogen per kilogram of parts.
PEGE’s published throughput backs that up. Its machines are rated at 150 to 600 kg of parts a day. At roughly a liter per kilogram, they’d want 150 to 600 liters of liquid nitrogen a day, which is the right order of magnitude for chambers that size.
Good to know: the first cycle of the day can cost four or five times a normal one, because the media and chamber steel start at room temperature. Batch your work. A machine that warms up between short runs uses far more nitrogen than one running cycles back to back, and that’s what the hold-cold idle mode on most machines is for.
What that means by shop
The working-day figure sizes the storage tank. The average per day across a full week sizes the generator, because it keeps producing through the weekend.
| Operation, five days a week | LN2 on a working day | Average per day over a week |
|---|---|---|
| Small machine, a few batches a day | 50 to 150 L | 35 to 110 L |
| One mid-size machine, most of one shift | 250 to 500 L | 180 to 360 L |
| One machine on two shifts, or two machines on one | 500 to 1,000 L | 360 to 715 L |
| A dedicated deflashing cell | 1,000 L and up | 715 L and up |
These are engineering estimates. Weigh a dewar before and after a shift, or fit a level gauge on the tank, and you’ll have your own number within a week.
In-house machine or service bureau?
Both are common. The choice mostly comes down to volume and lead time.
- A service bureau suits low or irregular volume, first articles and overflow. Turnaround of two to five days is typical. The better bureaus will run a free sample lot as a process evaluation, which is the cheapest way to find out whether your part deflashes well at all.
- An in-house machine suits steady volume, short lead times and parts you’d rather not ship twice. It also puts the nitrogen bill on your own meter.
The decision usually flips when per-piece charges and freight add up to more than a machine and its nitrogen would cost, or when the round trip starts to hold up your own deliveries.
Supplying the nitrogen
Swapping dewars is a constant small hassle in a deflashing cell. At the rates above, a machine running through a shift empties a 230 liter liquid cylinder in well under a day, so someone ends up wheeling cylinders while the line waits.
| Dewars (160 to 230 L) | Bulk tank | On-site generator with storage | |
|---|---|---|---|
| Fits | A machine used for a few batches a day | Multi-machine cells averaging more than about 960 L a day | One machine up to a full cell, up to about 480 L a day from one Titan 480, or about 960 from two |
| Up-front | Low | Tank, plinth, permits, piping | The machine, installed |
| Running cost | Highest per liter, plus boil-off and fees | Lower per liter, plus rental and fees | Mostly electricity, about $0.14 to $0.21 per liter |
| Interruption | Change-outs mid-shift | Delivery schedule | Storage refills itself |
| Boil-off | High, especially over weekends | Moderate | Storage is kept topped up |
Before anything else, check the liquid supply pressure your machine wants. Published requirements range from about 2 bar to 7 bar across makers. That spread decides whether a generator can feed the machine directly or whether you need a pressure-building circuit.
Sizing a generator
| Shop profile | Average per day over a week | Titan setup | Storage |
|---|---|---|---|
| Small machine, a few batches a day | 35 to 110 L | Titan 60 up to 60 L a day, Titan 120 above that | 200 to 300 L |
| One mid-size machine, most of one shift | 180 to 360 L | Titan 240 up to 240 L a day, Titan 480 above that | 500 to 1,000 L (Titan 240) or up to 2,000 L (Titan 480) |
| One machine on two shifts, or two machines on one | 360 to 715 L | Titan 480 up to 480 L a day, two Titan 480s above that | Up to 2,000 L per unit |
| A dedicated deflashing cell | 715 L and up | Two Titan 480s up to about 960 L a day; a bulk tank beyond that | Up to 4,000 L across the two units, or bulk |
Storage matters more here than in most applications, because demand comes in bursts. A Titan 240 with a 1,000 liter tank can feed a machine drawing 80 liters an hour through a four-hour run. That’s 320 liters, more than the generator makes in a day, so the tank runs down through the week and the weekend tops it back up. Five runs use 1,600 liters, and seven days of production make 1,680.
Once a cell needs more than one Titan 480 can make, two units side by side double the output to about 960 liters a day. The second unit also gives you redundancy: if one generator is down for service, the other keeps the line running.
What it costs
Take a molder running one machine most of a shift: about 250 liters a day, 250 working days a year, so roughly 62,500 liters. At a realistic all-in delivered price of $2.00 per liter, that’s $125,000 a year. A Titan 240 makes up to 240 liters a day, seven days a week, and its tank carries the weekend’s output into Monday. That’s 87,600 liters a year of capacity against 62,500 used.
| Delivered | On site with a Titan 240 | |
|---|---|---|
| Up-front cost | None | $264,998 to buy the generator |
| Nitrogen, or the electricity to make it | $125,000 a year (62,500 L at $2.00) | $11,250 a year (62,500 L at about $0.18) |
| Maintenance | None | About $1,000 a year |
| Running cost per year | $125,000 | $12,250 |
| Saving per year | $112,750 | |
| Time for the generator to pay for itself | About 2.4 years | |
| Total over ten years, generator included | $1,250,000 | About $387,500 |
| Average cost per liter over ten years | $2.00 | About $0.62 |
The generator pays for itself once the yearly savings add up to its price. After that, you pay only for electricity and maintenance, about $0.20 a liter. The ten-year lines spread the purchase price over a decade, since a generator lasts well over ten years.
Practical notes
- Watch the humidity. Cold parts and cold media pull water out of humid air. It frosts the chamber, makes media clump and stick, and settles on parts as they warm. Machines are purged with dry nitrogen for this reason, and one patented design keeps a positive purge running for up to two hours after a cycle while the components warm. Some molders in humid plants have moved deflashing to the night shift to avoid afternoon humidity. Condition the room, dry the media air, and warm parts under a purge.
- Media wears out. Polycarbonate rounds off and breaks down. Replace it on a cycle count, not when quality starts to slip.
- Monitor oxygen. One liter of liquid nitrogen becomes about 694 liters of gas at room temperature, and a deflashing machine releases all of it unless the exhaust is ducted outside. The US Chemical Safety Board counted 85 nitrogen asphyxiation incidents in US workplaces between 1992 and 2002, with 80 deaths and 50 injuries. OSHA requires workplace oxygen to stay between 19.5% and 23.5%.
- Put sensors where the gas goes. Cold nitrogen is denser than room air. A slug released when the door opens drops to the floor, then warms, becomes buoyant and rises back through the operator’s breathing zone. Exhaust at both high and low level, and put sensors in the breathing zone, around 4 feet up. The white cloud you see is condensed water vapor, not nitrogen, and the hazard lasts longer than the fog.
- Magnesium needs a different machine. Magnesium die castings need explosion-protected equipment. Showtop’s magnesium series holds the chamber below 1.4% oxygen with automatic nitrogen injection, an in-chamber oxygen sensor and a pressure relief outlet. That’s a second, continuous nitrogen demand on top of cooling.
- Purity doesn’t matter here. The nitrogen only has to be cold and inert. These machines run on over 98% nitrogen, which is what an on-site generator produces.
Frequently asked questions
What is deflashing?
Deflashing means removing flash, the thin film of excess material squeezed out where the halves of a mold or die meet. Shops do it by hand with knives and scrapers, or with tumbling, abrasive blasting, thermal energy deflashing, ultrasonic vibration, dry ice blasting or cryogenic deflashing. The right method depends on volume, material and how much marking the part’s surface can take.
How much does a cryogenic deflashing service cost?
Nitrofreeze, one of the few service bureaus that publishes figures, quotes anywhere from under a hundredth of a cent to several dollars per part, and says the cost usually runs 10% to 20% of the part’s value. It has no minimum quantity but charges a $125 minimum per lot, with same-day or next-day service for a small premium. The first sample lot of a new part is processed free.
Is cryogenic deflashing cheaper than trimming by hand?
At production volume, usually. In one case reported by Products Finishing, hand trimming a silicone part took at least 20 seconds a piece, and switching to cryogenic deflashing saved six hours of labor per 1,000 parts. An aerospace molder trimming PEEK parts cut its deflashing cost by nearly 85% the same way. Solvay’s own comparison of methods calls hand trimming simple but not cost-effective for large volumes.
How does it compare with vibratory tumbling or abrasive blasting?
On cosmetic parts, it usually leaves a better surface. Vibratory tumbling mixes plastic media with abrasives such as silica or aluminum oxide and leaves dust on the parts that has to be cleaned off, and alumina blasting roughens the surface. In Solvay’s side-by-side test, cryogenic deflashing removed flash without damaging the surface, at up to 180 parts in a batch of about three minutes. It costs more to set up: Solvay rated cryogenic equipment at 20 on a relative investment scale, against 5 to 10 for blasting, with nitrogen as the main running cost.
When is dry ice blasting the better choice?
For parts too large for the 24-inch baskets cryogenic machines use, and for very fine features. Nitrofreeze reports clearing openings as small as 0.003 inch with dry ice, far below what polycarbonate media can reach. Dry ice turns to gas on impact, so nothing is left inside the part afterward. The trade-off is that dry ice blasting is largely a manual process, while cryogenic deflashing runs in automated batches.
What materials can be cryogenically deflashed?
Most molded rubbers and plastics, and some metal parts. Service bureau lists include silicone, Viton, EPDM, nitrile, neoprene, butyl and urethane, plus plastics such as acetal, nylon, PPS, PEEK, polycarbonate, polypropylene, PET, ABS and liquid crystal polymer. They also cover aluminum and zinc die castings, PH stainless steels and beryllium copper. If your material isn’t listed, the free sample lot is the quickest way to find out.
What is a cryogenic tumbler?
It’s a machine that freezes parts and tumbles them to knock off external flash and burrs, without a wheel throwing media at them. Because nothing is fired into the part, it only reaches outside edges. Flash inside holes and cross-holes needs a blast machine.
Do parts need cleaning after cryogenic deflashing?
Usually not. The polycarbonate media is non-abrasive and leaves little dust or residue behind. Parts with blind holes or fine features can trap pellets and need a check, and medical parts that need an especially high level of cleanliness are often given an ultrasonic clean afterward.
Is on-site nitrogen right for your deflashing cell?
If a machine runs most days, if someone is changing dewars mid-shift, or if your nitrogen line item has gone up at every renewal, on-site generation is worth pricing. If you deflash a few batches a month, dewars are simpler and you should stay with them. The way to know is to put a year of nitrogen invoices next to what a generator costs to buy and run. Our free liquid nitrogen supply audit does exactly that, and you can compare the Titan range any time.
NASA, the U.S. Air Force and SOCOM already produce their own liquid nitrogen with Titan generators. See the full list on the clients page.
Rutherford & Titan is an American liquid nitrogen company based in the USA. We design, build, install, and support liquid nitrogen generators nationwide, with US-based service and remote diagnostics.
Sources: Nitrofreeze, “The five T’s of cryogenic deburring and deflashing”, “Cryogenic deflashing vs. cryogenic deburring” and equipment specifications; Barwell Freeze Trim-NX brochure; PEGE cryogenic deflashing machine model table; Jucai SD-series technical parameters; Showtop NS-60T and explosion-proof MG series specifications; Cryogenic Systems and Parts equipment and process pages; Solvay Specialty Polymers, “Comparison of deflashing methods for molded components”; Dow Corning (K. Larson), “Low temperature characteristics of silicones”; Chemours Viton selection guide; ASTM D2137 and ASTM D746; US Chemical Safety Board Safety Bulletin 2003-10-B, “Hazards of nitrogen asphyxiation”; NIH Office of Research Facilities Technical Bulletin 109; Air Products Safetygram 7; NIST thermophysical properties of nitrogen.
More from Rutherford & Titan
Stay ahead on on-site nitrogen
Cost benchmarks, application guides and product updates, a few times a year.











